Browse all practice questions for the 4th Year Lineman Apprentice Practice Exam. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

Energize Your Career with the 2026 Lineman Apprentice Exam – Power Up and Pass! course image
All questions

These questions are part of the practice quiz. Start practicing

  • What is considered the most reliable underground electrical service?
  • According to Blondel's Theorem, how many stators are required to properly meter a service with multiple wires?
  • What method is used for alignment during the erection of steel on concrete pads?
  • In what unit is impedance measured?
  • What is the total current in a 14,400 volt overhead circuit with a power rating of 300 Kva and a real power load of 240 Kw?
  • Which wire type is often indicated for a phase 4-wire transformer bank?
  • Which unit of measure represents "real" power?
  • What type of equipment uses a hand-driven generator?
  • What term describes the total opposition to current flow in an alternating current circuit?
  • If a 100 Kvar capacitor is installed in the circuit, what will be the new power factor?
  • What is the minimum bending radius of primary underground cable in relation to its diameter?
  • What are the two general classifications of power cables?
  • Which trigonometric function is utilized for solving 'z' in a right triangle?
  • Which insulation type is not known for high flexibility but provides good thermal resistance?
  • What is a key difference between a "Scott" transformer and a "Conventional" transformer?
  • Which transformation type would decrease voltage from a high level to a lower level?
  • What insulation medium is used for cables over 45 kV?
  • Which situation is more likely to create ferro-resonance in a transformer bank?
  • What is the typical unit for measuring frequency?
  • If a voltmeter connected to a 14,400 volt bus reads 120.8 volts, what is the voltage on the bus?
  • What unit measures Reactive power?
  • Why is the second source of supply significant in critical electrical loads?
  • What is the primary purpose of stranding conductors?
  • What type of circuit allows power to flow in one path only?
  • What is the minimum acceptable test voltage for a good sacrificial anode?
  • Which grounding technique is primarily used for safety in electrical systems?
  • What is the unit of measure for both capacitive and inductive reactance?
  • What is the calculated value of the hypotenuse in the given scenario?
  • What is the potential risk of not addressing ferro-resonance in transformer systems?
  • Which multiplier is used for calculating voltages in a three-phase system?
  • What is the calculation for determining the required fuse size?
  • When two linemen are working from an elevated position, must they work on the same phase at one time?
  • What is the primary purpose of electromagnetic detectors in cable testing?
  • What procedure is used to ensure a sacrificial anode is in proper operating condition?
  • What type of underground electric system has a single source of feed?
  • What is the voltage of the high side coil mentioned?
  • What is the purpose of a conductor shield in a cable?
  • What is another name for a bottom connected meter?
  • For a system voltage of 240, 3-phase with 150 amps and a power factor of 80%, what is the Kw power load?
  • What is the unit of measure for capacitance?
  • How would you calculate the inductive reactance of a 53.08 millihenry inductor in a 60 cycle circuit?
  • What fuse size would be required for the capacitor when calculating the new power factor with a 100 Kvar capacitor?
  • What is the minimum bending radius of secondary underground cable in relation to its diameter?
  • When removing capacitors rated over 600 volts, how long should you wait before grounding and shorting out terminals?
  • What term refers to the highest of the average load during a metering period?
  • What device on a kilowatt-hour meter counts the revolution of the rotating element?
  • Which of the following best describes True Power?
  • What should be inspected for damage during daily checks of rubber gloves?
  • How is the high side coil current calculated?
  • What is an assembly containing both the potential and current coils called?
  • What is the maximum number of automatic sectionalizing devices that can be placed in series on a single phase circuit?
  • What is the unit of measure for reactive power?
  • True or False: The main difference between a boost and buck transformer connection is the reversal of the series winding connections.
  • What is the normal low-side rating of a potential transformer?
  • What does the load factor represent in electrical terms?
  • What advantage does plastic have for high voltage insulation on underground cables?
  • Which method is commonly used for draining manholes?
  • What procedure can inadvertently reverse the direction of rotation of a customer's three-phase motor?
  • What does a step-up transformer do to the current for economical power transmission?
  • If the high side of an autotransformer is supplied with 2400 volts, what is the low side voltage if formed by tapping from one end of the coil to the center?
  • Are all three-phase motors considered "induction" running motors?
  • What is the high side coil voltage of the 50 kVA transformer?
  • What is the significance of the right triangle method in electrical circuits?
  • Which term refers to the rate at which work is being done in an electrical context?
  • What function does a "sacrificial anode" serve in underground electrical apparatus?
  • What trigonometric function is used to solve for the angle of a right triangle?
  • What term refers to the highest demand measured over a specified period?
  • For a specific value of voltage, what relationship exists between current and resistance?
  • What is the most common cause of faults in underground systems?
  • What factor is used to size fuses in relation to the load current?
  • Which type of current flow opposes rapid changes due to its inductive nature?
  • What is a significant disadvantage of concentric underground cables?
  • What is the purpose of a manhole in underground systems?
  • Is it possible to use potential transformers without current transformers for metering purposes?
  • Given a system voltage of 13,200 with a balanced current load of 30 amps and a power factor of 85%, what is the Kva power load?
  • What is the biggest disadvantage of an underground electrical system?
  • What is the minimum safe working distance phase to phase for system voltages up to 15,000 volts?
  • A circuit with excessive inductance is typically classified as which type?
  • Which unit is used to measure apparent power?
  • What multiplier is used to calculate high side line current from coil current in a delta connection?
  • The measure of which electrical characteristic opposes current flow due to changes in voltage is called what?
  • What capacity does a sectionalizer have to interrupt?
  • What unit measures "apparent" power?
  • What is the resulting fused size when multiplying the calculated current by 1.25?
  • An overhead electric distribution system typically contains which type of reactive power?
  • Fault indicators are placed behind which components?
  • Which part of a motor consists of three single-phase windings spaced 120 degrees apart?
  • What does a demand meter measure?
  • What effect do autotransformers have on harmonic distortion in electrical systems?
  • To calculate the fuse for a transformer, what multiplier is used?
  • What threshold is often applied to the calculated fuse size for safety considerations?
  • Which of the following is a potential symptom of ferro-resonance?
  • What is the recommended practice when sectionalizing a "floated" wye transformer bank under conditions of ferro-resonance?
  • What is an example of the unit of measure of real demand load?
  • Which of the following is NOT classified as an underground test device?
  • In an aerial device, where is the preferred point for attaching the lanyard of a body belt?
  • When calculating the wattmeter multiplier, if a potential transformer is rated at 14400/120, what value is obtained?
  • What is the effect of increased capacity on capacitive reactance?
  • Which of the following are classified as instrument transformers?
  • What is the resulting impedance when a 40-ohm resistor is added in series to the circuit?
  • What is the leading cause of underground cable failures?
  • What type of cable insulation is typically used for low voltage applications?
  • What is the Kva power load for a system voltage of 240 with a balanced current load of 150 amps and a power factor of 80%?
  • What is the primary cause of low power factor in overhead systems?
  • What is the assembly used to connect an overhead line to an underground line known as?
  • What is the potential difference between two dissimilar metals in an electrolyte primarily dependent on?
  • What device is used to measure high resistance in cables?
  • What is the formula for calculating inductive reactance?
  • What does 'R' represent in the impedance calculation formula?
  • Why is oil and gas-filled cable considered more practical for high voltage applications?
  • How many fuses are required for the specified bank?
  • Which cable insulation has superior resistance to heat deformation and environmental stress cracking?
  • What is the value of current that can cause fibrillation of the heart?
  • What mechanism is used to measure electrical energy in a building?
  • How is the relationship between true power and apparent power expressed?
  • In a lightly loaded secondary side of a transformer bank, what is more likely to occur under ferro-resonance conditions?
  • What unit is used to measure resistance?
  • What is the primary function of a sectionalizer in an electrical circuit?
  • Zinc is considered a sacrificial metal to which material?
  • What is the primary function of primary reading meters?
  • Are OCR's on taps rated in adjacent sizes allowed to drop down by two sizes?
  • What electrical phenomenon can lead to inefficiencies in power distribution due to a concentrated current flow?
  • How are the windings within a motor commonly connected?
  • In electrical terms, what is the usual definition of 'capacity'?
  • What is an essential function of storm pumps in manhole drainage?
  • How does the current flow pathway through the body potentially affect safety?
  • What is the effect of reversing two phases of a three-phase motor?
  • How must electrical equipment be made to protect the public from tampering?
  • If a potential transformer (PT) is rated at 14400/120, what is the potential multiplier?
  • What does the minimum fault current value represent at a sectionalizing point?
  • What kind of humming is typically associated with transformers under certain conditions?
  • What method is used to calculate total impedance in an alternating current circuit?
  • What does an increase in impedance typically affect in an AC circuit?
  • What characteristic of an alternating current circuit opposes changes in current?
  • What term describes the opposition to current flow due to a change in voltage or current?
  • What type of cable insulation is made of closely woven cotton cloth coated with insulating varnish and rated from 600 to 23000 volts?
  • Which condition applies when linemen can safely work on different phases simultaneously?
  • At what power rating does the transformer bank operate?
  • What metal is commonly used for sacrificial anodes on underground equipment?
  • What type of circuit consists of a resistance and a capacitance?
  • When a transformer rated meter is changed due to overload, what is this process commonly known as?
  • Why are the secondary side connections of transformers typically grounded?
  • How do you determine the wattage being processed by a circuit using the multipliers derived from transformers?
  • What is the high side coil voltage for the 13800 3-phase 4-wire 10 kVA transformer?
  • Which type of meter typically records energy consumed for billing purposes?
  • How many fuses does the 50 kVA transformer bank require?
  • How is the potential coil connected in a typical meter setup?
  • What does a megohmeter specifically measure?
  • Why is burying junk pieces of wire in trenches forbidden for line personnel?
  • What is the high side line current for the 50 kVA transformer?
  • What term is used for an underground room intended for pulling and splicing cables?
  • What is the process of determining the type of fault called?
  • What type of power is indicated by the term 'vars'?
  • Autotransformers with ratios no greater than 2-1 are more efficient and have less harmonic distortion. True or False?
  • How does the high side line current compare to the coil current in a wye bank?
  • What is the formula for calculating capacitive reactance?
  • What type of connection is more likely to create ferro-resonance while switching?
  • At a power factor of 100%, what is the relationship between real load and total load?
  • How do you calculate the high side coil current for the 13800 3-phase 4-wire 10 kVA transformer?
  • What is one of the primary disadvantages associated with underground power systems?
  • Under what condition would a transformer rated at 120/240 or 240/480 have internal connections?
  • What is the unit of measure for inductive reactance?
  • Which term describes the amount of electricity used at any given moment?
  • What procedure is used when a transformer rated meter becomes overloaded?
  • What unit measures "real" power?
  • True or False: A dead front transformer contains exposed live parts.
  • What is the unit of measure for real power in an electrical system?
  • Which device is commonly used to measure high currents?
  • Total opposition to current flow in an alternating current circuit is referred to as?
  • In the context of metering, which term is related to the highest demand recorded?
  • What is the multiplier used to calculate the fuse for a capacitor?
  • Which factors can lead to faults in underground wiring systems, apart from human error?
  • Which of the following devices indicates depth of a cable?
  • What is the primary effect of placing temporary grounds on the floated neutral of a transformer bank during switching?
  • What is the connection type of a 13800 3-phase 4-wire 10 kVA transformer?
  • What is the unit of measure for inductance?
  • Which configuration is used to increase the starting torque of a three-phase motor?
  • What does the register in a kilowatt-hour meter track?
  • Which component is commonly involved in cost-sharing agreements between utilities?
  • What term relates to the phenomenon where current is conducted near the surface of an alternating current conductor?
  • What is the typical sequence of operations for OCR's protected by fuses?
  • What is the power stored in reactance known as?
  • Which configuration is indicated for the transformer bank connection?
  • What size of submersible transformers requires the use of an open grating for proper ventilation and cooling?
  • Which instrument is used to measure electrical resistance?
  • What is the term used for the product of voltage and current in electrical systems?
  • How many fuses are required for the transformer bank described?
  • What is the situation called when the capacitance of a cable cancels the inductive effect of a transformer?
  • Which measurement is most associated with electrical power consumption?
  • Which method is typically required for fault localization in cable systems?
  • Which component in an electric motor is mainly responsible for generating rotational motion?
  • What are the two basic types of underground faults?
  • If an overhead circuit has a total apparent power of 300 Kva and a real power load of 240 Kw, what is the percentage power factor?
  • What type of transformer can be used to electrically isolate?
  • What is the function of a potential transformer in a high voltage circuit?
  • During which condition is a transformer bank likely to experience issues related to ferro-resonance?
  • What general classification of power cables is designed to prevent leakage and external interference?
  • What type of meter is designed to register actual readings?
  • What is one reason to regularly check the status of potential and current transformers?
  • Which of the following factors is NOT a determinant of the rate of activity between two dissimilar metals?
  • What should be monitored when dealing with the secondary side of a transformer?
  • What are the two classifications of underground fault locating equipment?
  • Which term accurately describes a method of locating faults underground by using signals?
  • How is the polarity of instrument transformers classified?
  • What is the reactive load in the same overhead circuit rated at 300 Kva with a real power load of 240 Kw?
  • What type of signaling known as 'impedance' does an AC circuit encounter?
  • What is the primary purpose of instrument metering?
  • Which of the following is classified as a reactive load?
  • System voltage is defined as which value of the electrical system?
  • What can be said about the quality of reactive power?
  • What is the measurement unit for metered reactive load?
  • What type of transformer is used to increase voltage on a feeder by 5 or 10 percent?
  • Which cable type is rated at 5000 volts and features helically wrapped paper tapes around the conductor?
  • Which unit is used for measuring "reactive" power?
  • Which type of meter must carry the entire load current through the meter?
  • Which device is essential for proving that a cable is de-energized?
  • What happens in a circuit on the secondary side of a current transformer (CT) with an open connection on a fully loaded line?
  • Which formula is used to calculate impedance?
  • What term refers to the cooperation between utilities for cost sharing?
  • What is a major factor that reduces the reliability of underground systems?
  • Which unit measures metered energy?
  • What type of underground electric system has secondary mains supplied by multiple primary feeders?
  • A 4 wire configuration on the high side of the system indicates which type of system?
  • How much is the Kw power load for a circuit with a 13,200 system voltage, 30 amps, and a power factor of 85%?
  • Which term refers to the measure of total opposition to current flow in a circuit?
  • What type of load would generally require a 3-phase transformer connection?
  • In the context of transformers, what does CT stand for?
  • What is the calculated high side coil current for the 50 kVA transformer?
  • What do we call power that is dissipated by resistance, measured in watts?
  • At what Kvar rating does a capacitor bank require a vacuum or oil switch for sectionalizing?
  • What is the primary reason for grounding the tank of the transformers?
  • What is a common characteristic of an induction motor?
  • What component is crucial in preventing electrical overload situations?
  • In terms of electrical circuits, what does the symbol 'X' represent?
  • With regard to electrical safety, what does the term "joint" refer to in utility contexts?
  • What is the primary function of fuses in a transformer bank?
  • What is the unit of measure for apparent power?
  • What is the measure of the angle in the right triangle described?
  • Which of the following is a measure of electrical resistance?
  • What type of transformer setup could provide electrical isolation for safety purposes?
  • What property of an alternating current circuit opposes changes in voltage?
  • What is the total opposition to current flow in an alternating current circuit called?
  • Is bending too sharply during installation the only way an air void can be created in an underground cable?
  • How is the high side coil current calculated for the 50 kVA transformer?
  • What does the "Class" of a meter indicate?
  • Which of the following best defines 'maximum demand' in electrical consumption?
  • Why are underground secondary faults considered easier to locate?
  • Which formula is used to calculate the current from the transformer's KVA rating and voltage?
  • What is the primary objective of fault location on overhead and underground systems?
  • What does the diversity factor measure?
  • For proper function, what property should transformers have regarding their cooling methods?
  • Is the path of current flow more likely to take the path of the dermis layer than the epidermis?
  • What does the term "dead front" refer to in electrical equipment?
  • Which device is specifically designed to indicate when fault currents have passed through?
  • Is it necessary for a dissimilar metal to be connected to a cable for corrosion to occur on that underground cable?
  • What is the calculated high side coil current for the 13800 transformer?
  • Phase transformation can be accomplished by the use of:
  • Which type of cable is less affected by moisture due to its sealed nature?
  • What phenomenon is likely to occur if a transformer bank is not loaded adequately during operation?
  • Mechanical and thermal meters are types of what?
  • What is the unit of measure for impedance?
  • What is a key characteristic of a radial circuit?
  • What describes a chemical reaction within an electrolyte that leaves a metal with excess electrons?
  • What is the current multiplier for a current transformer (CT) rated at 200/5?
  • Voids within the high voltage insulation of underground cable can lead to failure due to what reason?
  • A transformer that is additive in polarity has a coil voltage of what value?
  • Where can you find the minimum and maximum fault current values?
  • What is the calculated fuse size for the transformer bank?
  • What term describes the opposition to current flow in a direct current circuit?
  • How often should rubber gloves be inspected while in use?
  • What is the normal low-side rating of a current transformer?
  • What is the minimum diameter for handlines used in electrical work?
  • Which of the following statements is true regarding overhead and underground fault location?
  • What is a system designed for critical loads with a second source of supply?
  • Which device is used to secure electrical equipment against tampering?
  • Which of the following is a medium commonly used for insulation in high-voltage cables?
  • What is the high side line current as per the calculations?
  • What unit is used to measure capacitive reactance?
  • What type of metal is installed in the ground and connected to a submersible transformer's tank to prevent corrosion?
  • What does a 3 wire configuration on the high side of the system indicate?
  • An autotransformer would be practical in which of the following applications?
  • Which term is used to describe electricity consumption patterns over a specific period?
  • What primarily causes a low power factor in underground systems?
  • What is the fuse size required for the 50 kVA transformer bank?
  • How is the high side coil voltage represented in electrical engineering standards?
  • In an underground electrical system, a looped design is chosen for which of the following reasons?
  • What is the multiplier used in the calculation of voltages on a two-phase system?
  • What does the process of confirmation ensure on a faulted circuit?
  • What device sends pulses into a cable to display reflections caused by changes in electric characteristics?
  • Which type of power does inductance relate to in alternating current circuits?
  • What is the primary function of a booster transformer?
  • What is the connection type of a 7200 3-phase 3-wire 50 kVA transformer?
  • What must be done to the exposed open ends of underground cable during construction?
  • What is the primary purpose of a sacrificial anode?
  • What term refers to work done and measured in kilowatt-hours?
Subscribe

Get the latest from Examzify

You can unsubscribe at any time. Read our privacy policy